Zaron Energy — Whole-Home Tool

Build Your Whole Backup Plan.

Combine the appliances that matter during an outage. Set each load's real watts, how long it must run, and any startup requirement. The calculator keeps energy capacity and inverter output separate.

Battery capacity answers “how long?” Inverter output answers “can it run or start?” You need both.
How it works

One calculator. Every essential load.

Start from the Appliance Database, import a configured appliance automatically, or build the plan here from scratch.

01
Add loads

Refrigeration, internet, pumps, HVAC, office, cooking and more.

02
Set equivalent runtime

Use actual operating time during the outage, not necessarily the full outage duration.

03
Check energy + output

Battery kWh and maximum simultaneous / startup demand are shown separately.

Step 01

Build Your Essential-Load List

LoadRunning WUse hoursStartup W
No loads yet.Click an appliance above or add a custom load.

Why this calculator is different

It Separates Energy From Power.

Many bad backup estimates mix watt-hours, running watts and motor startup into one number. They answer different questions.

BATTERY

How Long?

Watt-hours and kilowatt-hours determine how much energy is stored for the outage.

INVERTER

Can It Run?

Continuous AC output must support the loads that are operating at the same time.

STARTUP

Can It Start?

Compressors and motors may require short-duration startup capability above normal running power.

DON'T SIZE BY kWh ALONEPOWER + ENERGY BOTH MATTER

A Huge Battery Can Still Fail a Motor Load.

If the inverter cannot supply the required voltage or startup power, stored energy does not help. Zaron keeps those constraints visible instead of hiding them behind a single “battery size” result.

Methodology

Transparent Math. Editable Inputs.

Input A Running watts
Actual or planning input for each essential load.
W
Input B Equivalent runtime
How many hours that load actually operates during the outage window.
h
Step 01 Load energy
Running watts × equivalent runtime for every load.
Wh
Step 02 Whole-plan energy
Sum the watt-hours from all loads.
Σ Wh
Step 03 System efficiency
Divide by 0.90 Zaron planning efficiency.
÷ 0.90
Step 04 Sizing margin
Multiply by 1.20 Zaron planning margin.
× 1.20
Output A Recommended battery
Whole-plan stored-energy target.
kWh
Output B Startup / output target
Largest entered startup requirement; verify simultaneous-load and voltage constraints separately.
W / VA